mirror of
https://github.com/mii443/qemu.git
synced 2025-08-22 15:15:46 +00:00
hw/tpm: TIS on sysbus: Remove unsupport ppi command line option
The ppi command line option for the TIS device on sysbus never worked and caused an immediate segfault. Remove support for it since it also needs support in the firmware and needs testing inside the VM. Reproducer with the ppi=on option passed: qemu-system-aarch64 \ -machine virt,gic-version=3 \ -m 4G \ -nographic -no-acpi \ -chardev socket,id=chrtpm,path=/tmp/mytpm1/swtpm-sock \ -tpmdev emulator,id=tpm0,chardev=chrtpm \ -device tpm-tis-device,tpmdev=tpm0,ppi=on [...] Segmentation fault (core dumped) Signed-off-by: Stefan Berger <stefanb@linux.ibm.com> Reviewed-by: Eric Auger <eric.auger@redhat.com> Message-id: 20230713171955.149236-1-stefanb@linux.ibm.com
This commit is contained in:
@ -93,7 +93,6 @@ static void tpm_tis_sysbus_reset(DeviceState *dev)
|
||||
static Property tpm_tis_sysbus_properties[] = {
|
||||
DEFINE_PROP_UINT32("irq", TPMStateSysBus, state.irq_num, TPM_TIS_IRQ),
|
||||
DEFINE_PROP_TPMBE("tpmdev", TPMStateSysBus, state.be_driver),
|
||||
DEFINE_PROP_BOOL("ppi", TPMStateSysBus, state.ppi_enabled, false),
|
||||
DEFINE_PROP_END_OF_LIST(),
|
||||
};
|
||||
|
||||
|
Reference in New Issue