The VOUT_MODE command is described in the PMBus Specification,
Part II, Ver 1.3 Section 8.3
VOUT_MODE has a three bit mode and 4 bit parameter, the three bit
mode determines whether voltages are formatted as uint16, uint16,
VID, and Direct modes. VID and Direct modes use the remaining 5 bits
to scale the voltage readings.
Reviewed-by: Hao Wu <wuhaotsh@google.com>
Acked-by: Corey Minyard <cminyard@mvista.com>
Signed-off-by: Titus Rwantare <titusr@google.com>
Message-ID: <20231023-staging-pmbus-v3-v4-2-07a8cb7cd20a@google.com>
Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org>
PMBus devices can send and receive variable length data using the
block read and write format, with the first byte in the payload
denoting the length.
This is mostly used for strings and on-device logs. Devices can
respond to a block read with an empty string.
Reviewed-by: Hao Wu <wuhaotsh@google.com>
Acked-by: Corey Minyard <cminyard@mvista.com>
Signed-off-by: Titus Rwantare <titusr@google.com>
Message-ID: <20231023-staging-pmbus-v3-v4-1-07a8cb7cd20a@google.com>
Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org>