s390x: Return specification exception for unimplemented diag 308 subcodes

The architecture specifies specification exceptions for all
unavailable subcodes.

The presence of subcodes is indicated by checking some query subcode.
For example 6 will indicate that 3-6 are available. So future systems
might call new subcodes to check for new features. This should not
trigger a hw error, instead we return the architectured specification
exception.

Signed-off-by: Janosch Frank <frankja@linux.ibm.com>
Cc: qemu-stable@nongnu.org
Message-Id: <20190111113657.66195-3-frankja@linux.ibm.com>
Reviewed-by: Christian Borntraeger <borntraeger@de.ibm.com>
Reviewed-by: David Hildenbrand <david@redhat.com>
Signed-off-by: Cornelia Huck <cohuck@redhat.com>
(cherry picked from commit 37dbd1f4d4)
Signed-off-by: Michael Roth <mdroth@linux.vnet.ibm.com>
This commit is contained in:
Janosch Frank
2019-01-11 12:36:57 +01:00
committed by Michael Roth
parent 422bf25df1
commit 1c9b86daec

View File

@ -130,7 +130,7 @@ out:
} }
return; return;
default: default:
hw_error("Unhandled diag308 subcode %" PRIx64, subcode); s390_program_interrupt(env, PGM_SPECIFICATION, ILEN_AUTO, ra);
break; break;
} }
} }